IdeaPro "Outdoor heat pump unit ISW-SF1 series"

Operating ambient temperatures

Heating mode
- 25
... + 43 °C

Suggested retail price

0-hrv.

    Multi-Bend Heat Exchanger

    Increased heat. This unit uses the heat exchangers with tubes of a special design, the inner surface of which has trapezoidal notches "Innergrove cooper", which provides maximum heat transfer surface area increased. Due to this heat increases by 28%, reduced power consumption, and hence increases the efficiency of the system.

    Sine-Wave Inverter

    Technology 180° -gradusnogo wave inverter conversion - control voltage without the "pulse" effects (jagged sinusoid).

    Compared with the current standard of 120° rectangular wave has the following advantages:

    1. Ability to work with a wider range of supply voltage and frequency.
    2. Most of the energy efficiency and energy conservation.
    3. More soft start, lower noise and vibration.
    4. more control.

    Wi-Fi Control

    Conditioners can optionally be equipped with a Wi-Fi module that allows the user to monitor and remotely control the air-conditioner from a smartphone or tablet from anywhere in the world.

    Compresor DC inverter

    Compressor with inverter DC can increase the efficiency of the air conditioner, thus reducing power consumption saves your costs. This system is much more economical and safer than air conditioners with a constant output of the compressor.

    The heater of the outdoor unit pallet

    Подогреватель поддона наружного блока устанавливается для обеспечения полного удаления воды образовавшейся в результате оттайки теплообменника наружного блока, после проведении режима "разморозки". Может изготавливаться из различных материалов.

    Heat pumps (HP) of the ISW series are available in split versions to meet the needs of the client.

    Compared to standard heat pumps in this power range, which usually need to be integrated with a boiler or electric heaters, the ISW heat pump is designed to operate in monovalent mode, without the need for additional heaters or integrated heating elements.

    In this way, it guarantees maximum energy savings and at the same time avoids the need to connect to a traditional heating network.

    The ISW series HP model range will be supplied with a thermal output of 10,16,18,24, 28 kW (capacity is indicated at A7-W35 temperatures), the 10kW model is powered by 220V / 1F, the rest of the models are powered by 380V / 3F, all they are without electric heating elements in the indoor unit. Electricity consumption 2.2 - 3.6 - 4.1 - 6.5 - 8 kW, respectively (at rated load).

    The outdoor units use specialized Panasonic EVI DC-inverter compressors running on R-410a freon, the outdoor unit fan motors are also equipped with DC motors, which made it possible to achieve energy efficiency in class A + according to the EU Technical Regulation for heating heat pumps.
    Each outdoor unit comes with 4 m.p. copper pipe - flared at the ends, with nuts, in thermal insulation - for quick installation of the interblock route.

    FULL DC INVERTER  HOT WATER + HEATING+COOLING EVI HEAT PUMP (SPLIT)
    IDEA PRO MODEL Зовн / внутр блоки ISW-10SF1-DN1 / ISW-10SF1-SPM ISW-15SF1-DRN1 / ISW-15SF1-SPM ISW-18SF1-DRN1 / ISW-18SF1-SPM ISW-24SF1-DRN1 / ISW-24SF1-SPM ISW-32SF1-DRN1 / ISW-32SF1-SPM
    Working  Temperature Range   -2543
    Power Supply 220-240V/50Hz 380-415V/50Hz 380-415V/50Hz
    A7W35 Heating capacity (min-max) (kW)  10(3-11) 15(4-16) 18(4-20) 24(5-27) 32(5-35)
    Input power  (kW)  2.30 3.72 4.42 6.00 8.00
    Rated current (A)  10.50 5.70 6.70 9.10 9.10
    COP  3.75~4.6 3.82~4.58 376~4.62 3.9~4.6 3.74~4.58
    A2W45 Heating capacity(min-max) (kW) 7.8(3-8) 12.5(5-13) 15(4-16) 19(5-20) 25(5-27)
    Heating input power(kW) 2.32 3.80 4.55 5.80 7.70
    Rated current (A)  11.00 5.80 7.00 9.00 12.00
    COP   3.36 3.30 3.30 3.28 3.25
    A35W7 Cooling Capacity/EER (kW) 7/2.81 11/2.8 14/2.8 19/2.7 25/2.75
    Rated Cooling Input Power/Current(kW/A) 2.5/11.3 3.95/6.1 5.0/8.0 7.0/10.0 9.1/14
    Heating Outlet hot water temperature range () 25-60
    Cooling Outlet water temperature range () 7-12
    IP Grade (Level of protection) IPX4
    Anti-electric shock Rate
    Noise (dB(A)) 55 60 60 ≤70 ≤70
    Net weight/Gross weight(kg) 105/115 160/175 190/205 220/215 250/215
    Diameter of pipe (mm) DN25 DN25 DN32 DN32 DN32
    Cabinet material plate Galvanized steel/Spray/Gray
    Machine size Outdoor unit (W*D*H) 880*420*790 930*410*1270 1018*450*1366 1150*480*1440 1240*480*1630
    Indoor unit (W*D*H) 380*330*685 380*330*685 450*330*815 550*420*920 550*420*920
    Packing  size(W*D*H) Outdoor unit (W*D*H) 980*520*970 1030*510*1450 1120*550*1480 1300/580/1600 1380/580/1730
    Indoor unit (W*D*H) 420*450*720 420*450*720 520*420*910 650*520*1010 650*520*1010
    Compressor Panasonic Rotary  EVI DC inverter / Mitsubishi Inverter
    Refrigerant/Weight (Kg) R410/2.2 R410/ 2.6 R410/ 2.8 R410/ 3.6 R410/ 4.6
    Fan Motor DC VariableSpeed Motor
    Condenser SS 316 Brazed Plate Heat Exchanger
    Water pump Wilo Wilo Wilo Grundfos Grundfos
    Expansion tank 2L 2L 2L 5L 5L
    Four-way valve Sanhua Sanhua Sanhua Sanhua Sanhua
    Controller 7m Wired controller touch screen display + WIFI controller
    Copper pipe Diameter High/Low  (inch) 3/8"+ 5/8" 1/2" + 7/8" 
    Expansion valve Sanhua 
    Water Road Electric Heater Optional (2kW Extra) Optional(2kW Extra)
    Low-voltage switch 0.15/0.05MPa  0.15/0.05MPa  0.15/0.05MPa 
    High-voltage switch 3.6/4.2MPa  3.6/4.2MPa  3.6/4.2MPa 
    Package Polywood packing
    Weight Outdoor unit (kg) 68 95 105 155 185
    Indoor unit (kg) 32 37 40 75 80
    Remark:
    A7W35 working condition: Dry bulb temperature 7, Wet bulb temperature6. Outlet water temperature 35.
    A2W45working condition: Dry bulb temperature 2, Wet bulb temperature1. Outlet water temperature 45℃.
    A35W7 cooling conditions: Ambient temperature 35°C, inlet water temperature 12°C, outlet water temperature 7°C.